Cura is generating temperature commands in the wrong order. I need to swap lines 6 and 7 below so that both the printhead and bed can begin to heat at the same time.
Is this code generation configurable in Cura?
5 ;Generated with Cura_SteamEngine 2.5.0 6 M190 S60 ; set bed and block 7 M104 S215 ; set printhead, don't block 8 M109 S215 ; set printhead, block
1 Answer
You can do so by placing this at the top of the start code under machine settings (tested on 2.6.1).
M104 S{material_print_temperature} M190 S{material_bed_temperature}